369 lines
8.5 KiB
PL/PgSQL
369 lines
8.5 KiB
PL/PgSQL
drop function if exists mmt_staging2.fn_BUDNI_HDL_ODS;
|
|
CREATE OR REPLACE FUNCTION mmt_staging2.fn_BUDNI_HDL_ODS(p_file_syspk int)
|
|
RETURNS text AS $$
|
|
declare __test_instance_id int;
|
|
declare __file_syspk int;
|
|
declare __model text;
|
|
declare __make text;
|
|
declare v_state text;
|
|
declare v_msg text;
|
|
declare v_detail text;
|
|
declare v_hint text;
|
|
declare v_context text;
|
|
declare _error int;
|
|
begin
|
|
__file_syspk := p_file_syspk;
|
|
/************************************************************
|
|
Function Name:fn_BUDNI_HDL_ODS
|
|
Function Desc: This function populates data into ODS
|
|
File Format: BUDNI
|
|
Sheet Format: BUDNI_HDL
|
|
Creation Date:
|
|
Updation Date:
|
|
Author: compegence team
|
|
Function Call: select mmt_staging2.fn_BUDNI_HDL_ODS()
|
|
***************************************************************/
|
|
|
|
--delete from mmt_ods.test_instance
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
--
|
|
--delete from mmt_ods.test_instance_engine_info
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
--
|
|
--delete from mmt_ods.test_instance_tractor_info
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
--
|
|
--delete from mmt_ods.test_instance_tractor_info_misc
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
--
|
|
--delete from mmt_ods.budni_hydraulic_maint_of_lift_load_results
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
--
|
|
--delete from mmt_ods.budni_hydraulic_power_test_results
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
--
|
|
--delete from mmt_ods.budni_hydraulic_lifting_capacity_test_results
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
--
|
|
--delete from mmt_ods.budni_test_observations
|
|
--where test_file_sheet_format='BUDNI_HDL';
|
|
|
|
|
|
insert into mmt_ods.test_instance_tractor_info
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model,
|
|
tractor_engine_hp,
|
|
steering_type
|
|
)
|
|
select
|
|
client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,
|
|
model,
|
|
tractor_HP::int,
|
|
steering_type
|
|
from mmt_staging2.BUDNI_HDL_Spec_H1_block;
|
|
|
|
insert into mmt_ods.test_instance
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model
|
|
)
|
|
select
|
|
client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,
|
|
model
|
|
from
|
|
mmt_staging2.BUDNI_HDL_Spec_H1_block;
|
|
|
|
insert into mmt_ods.test_instance_engine_info
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model,
|
|
rated_rpm
|
|
)
|
|
select
|
|
client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,
|
|
model,
|
|
rated_rpm::int
|
|
from mmt_staging2.BUDNI_HDL_Spec_H1_block;
|
|
|
|
insert into mmt_ods.test_instance_tractor_info_misc
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model,
|
|
hydraulic_type,
|
|
pump_speed_at_rated_engine_speed_rpm,
|
|
oil,
|
|
lift_rod_type_lh,
|
|
lift_rod_type_rh,
|
|
lift_rod_length_lh,
|
|
lift_rod_length_rh,
|
|
lower_link_length_lh,
|
|
lower_link_length_rh,
|
|
pump_hp
|
|
)
|
|
select
|
|
client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,
|
|
model,
|
|
hydraulic_type,
|
|
Pump_speed_at_rated_engine_speed_rpm::numeric,
|
|
Oil,
|
|
Lift_Rod_type_LH,
|
|
Lift_Rod_type_RH,
|
|
Lift_Rod_Length_LH::numeric,
|
|
Lift_Rod_Length_RH::numeric,
|
|
Lower_link_Length_LH::numeric,
|
|
Lower_link_Length_RH::numeric,
|
|
Pump_HP::numeric
|
|
from mmt_staging2.BUDNI_HDL_Spec_H1_block;
|
|
|
|
|
|
/*block */
|
|
|
|
insert into mmt_ods.budni_hydraulic_power_test_results
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model,
|
|
pump_dlvry_rate_at_min_pressure_engine_speed_l_per_min,
|
|
max_hydraulic_power_kw,
|
|
pump_dlvry_rate_at_max_hydraulic_power_lmin,
|
|
pressure_at_max_hydraulic_power_mpa,
|
|
sustained_pressure_of_the_open_relief_valve_mpa,
|
|
tapping_point_relief_valve_test,
|
|
tapping_point_pump_perf_test,
|
|
tapping_point_temperature_of_hydraulic_fluid_c
|
|
)
|
|
select
|
|
client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,model,
|
|
Pump_delivery_rate_at_minimum_pressure_and_rated_engine_speed_l_min::numeric,
|
|
Maximum_hydraulic_power_kW::numeric,
|
|
Pump_delivery_rate_at_maximum_hydraulic_power_l_min::numeric,
|
|
Pressure_at_maximum_hydraulic_power_MPa::numeric,
|
|
Sustained_pressure_of_the_open_relief_valve_MPa::numeric,
|
|
tapping_point_relief_valve_test,
|
|
tapping_point_Pump_performance_test,
|
|
tapping_point_Temperature_of_hydraulic_fluid_C
|
|
from mmt_staging2.budni_hdl_power_test_block where ods_record=1
|
|
order by rank;
|
|
|
|
|
|
insert into mmt_ods.budni_hydraulic_maint_of_lift_load_results
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model,
|
|
force_applied_at_the_frame_kn,
|
|
temp_of_hydraulic_fluid_at_the_start_of_test_c,
|
|
elapsed_time_min,
|
|
cumulative_drop_in_height_of_lift_mm
|
|
)
|
|
select
|
|
client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,
|
|
model,
|
|
Force_applied_at_the_frame_kN::numeric,
|
|
Temperature_of_hydraulic_fluid_at_the_start_of_test_C,
|
|
Elapsed_time_minute::numeric,
|
|
Cumulative_drop_in_height_of_lift_mm::numeric
|
|
from mmt_staging2.budni_hdl_maintenance_of_lift_load_block;
|
|
|
|
/*block */
|
|
insert into mmt_ods.budni_hydraulic_lifting_capacity_test_results
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model,
|
|
test_condition,
|
|
height_of_lower_hitch_pt_above_ground_in_down_position_mm,
|
|
vertical_move_ment_with_lifting_forces_mm,
|
|
max_force_exerted_through_full_range_kn,
|
|
corresponding_pressure_mpa,
|
|
moment_about_rear_axle_kn_m,
|
|
max_tilt_angle_of_mast_from_vertical_degrees
|
|
)
|
|
select
|
|
client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,
|
|
model,
|
|
column5,
|
|
column6::numeric,
|
|
column7::numeric,
|
|
column8::numeric,
|
|
column9::numeric,
|
|
column10::numeric,
|
|
column11::numeric
|
|
from mmt_staging2.budni_hdl_Lifting_Capacity_Test_Block
|
|
where ods_record=1;
|
|
|
|
|
|
/* block */
|
|
|
|
|
|
insert into mmt_ods.budni_test_observations
|
|
(
|
|
client_id,
|
|
function_id,
|
|
test_file_ref_no,
|
|
test_file_format,
|
|
test_file_sheet_format,
|
|
tractor_make,
|
|
tractor_model,
|
|
srl_no,
|
|
characteristic,
|
|
category_evaluative_or_non_evaluative,
|
|
requirements_as_per_is_12207_2008,
|
|
values_declared_by_the_applicant_d_rqmt,
|
|
as_observed,
|
|
whether_meets_the_requirements_yn
|
|
)
|
|
select client_id,
|
|
function_id,
|
|
file_syspk,
|
|
file_format,
|
|
sheet_mnemonic,
|
|
make,model,
|
|
column3,column4,column7,column8,column10,column11,column12
|
|
from mmt_staging2.budni_hdl_test_obs_summary_block
|
|
where ods_record=1
|
|
;
|
|
|
|
|
|
select file_syspk into __file_syspk from mmt_staging2.BUDNI_FLD_Spec_H1_block;
|
|
select syspk into __test_instance_id from mmt_ods.test_instance where test_file_ref_no =__file_syspk;
|
|
select tractor_model into __model from mmt_ods.test_instance where test_file_ref_no =__file_syspk;
|
|
select tractor_make into __make from mmt_ods.test_instance where test_file_ref_no =__file_syspk;
|
|
|
|
update mmt_ods.test_instance_engine_info
|
|
set test_instance_id=__test_instance_id,
|
|
tractor_model =__model,
|
|
tractor_make=__make
|
|
where test_file_ref_no=__file_syspk;
|
|
|
|
|
|
update mmt_ods.test_instance_tractor_info
|
|
set test_instance_id=__test_instance_id,
|
|
tractor_model =__model,
|
|
tractor_make=__make
|
|
where test_file_ref_no=__file_syspk;
|
|
|
|
|
|
update mmt_ods.test_instance_tractor_info_misc
|
|
set test_instance_id=__test_instance_id,
|
|
tractor_model =__model,
|
|
tractor_make=__make
|
|
where test_file_ref_no=__file_syspk;
|
|
|
|
update mmt_ods.budni_hydraulic_maint_of_lift_load_results
|
|
set test_instance_id=__test_instance_id,
|
|
tractor_model =__model,
|
|
tractor_make=__make
|
|
where test_file_ref_no=__file_syspk;
|
|
|
|
update mmt_ods.budni_hydraulic_power_test_results
|
|
set test_instance_id=__test_instance_id,
|
|
tractor_model =__model,
|
|
tractor_make=__make
|
|
where test_file_ref_no=__file_syspk;
|
|
|
|
update mmt_ods.budni_hydraulic_lifting_capacity_test_results
|
|
set test_instance_id=__test_instance_id,
|
|
tractor_model =__model,
|
|
tractor_make=__make
|
|
where test_file_ref_no=__file_syspk;
|
|
|
|
|
|
update mmt_ods.budni_test_observations
|
|
set test_instance_id=__test_instance_id,
|
|
tractor_model =__model,
|
|
tractor_make=__make
|
|
where test_file_ref_no=__file_syspk;
|
|
|
|
v_context := '';
|
|
perform mmt_staging2.mmt_insert_db_error ( null, null, 1001, 'Compegence', __file_syspk ,'BUDNI','BUDNI_HDL' ,null,'ods', 'fn_BUDNI_HDL_ODS', v_state, v_msg, v_detail, v_hint, v_context,'success');
|
|
return v_context;
|
|
|
|
EXCEPTION when OTHERS then
|
|
|
|
GET STACKED DIAGNOSTICS
|
|
v_state = returned_sqlstate,
|
|
v_msg = message_text,
|
|
v_detail = pg_exception_detail,
|
|
v_hint = pg_exception_hint,
|
|
v_context = pg_exception_context;
|
|
|
|
perform mmt_staging2.mmt_insert_db_error ( null, null, 1001, 'Compegence', __file_syspk ,'BUDNI','BUDNI_HDL' ,null,'ods', 'fn_BUDNI_HDL_ODS', v_state, v_msg, v_detail, v_hint, v_context,'error');
|
|
return v_context;
|
|
|
|
|
|
end
|
|